电源中继车 Power Relay Vehicle

Mesian Power Relay Vehicle · Product Manual V4.1

Power Relay Vehicle

Power at your side — mission delivered. 241 kWh mobile energy storage trailer for field operations, emergency response and large events.

241 kWh50 kW220V / 380VIP54-20°C ~ 50°C

Sample vehicle photo · towing transit, roller door closed

A Battery Station That Moves — Not a "Better Generator"

Just as networks rely on relay stations, power can be relayed too: charge from the grid at night with off-peak rates, draw power anywhere by day; when capacity runs low, swap a battery cluster to keep going — without downtime. Low noise, zero emission (in e-drive mode), mobile, and quick-swap ready. In places with no grid, noise limits or zero-emission requirements, it is simply the better answer.

0 kWhNominal energy (15 clusters, LFP)
0 kWRated output (peak 55 kW / 10s)
≥0Cell cycle life (0.5C / 25°C / 80% EOL)
0 hFull charge from grid (30 kW)

Six Application Scenarios

Runtime estimated at 241 kWh × 90% usable capacity ÷ typical load; actual varies with load, temperature and line loss.

Field Engineering
Typical load 15 kWFull charge ≈ 14 h

Power tools, lighting and CCTV on construction sites, mines and pipeline jobs with no grid.

Emergency Rescue
Typical load 8 kWFull charge ≈ 27 h

Rapid-deployment power for command, communications and medical equipment at disaster sites.

Events & Shows
Typical load 25 kWFull charge ≈ 8.5 h

Diesel-generator replacement for stages, lighting and LED walls — quiet and zero emission.

Base Station Backup
Typical load 5 kWFull charge ≈ 43 h

Stable backup for remote towers and repeaters; remote deployment, low maintenance.

Temporary Rental
Typical load 12 kWFull charge ≈ 18 h

Daily / weekly rental for short-term needs — no purchase, maintenance or storage cost.

Expedition & Research
Typical load 7 kWFull charge ≈ 31 h

Camp power for survey and research teams; altitude ≤ 2000 m, wide temperature range.

Four Core Advantages

80%+ Energy Cost Saving

Grid off-peak charging costs roughly 1/5 of diesel generation; overall energy cost cut by 80%+ in typical site conditions (estimated).

241 kWh Large Capacity

15 modular LFP clusters, multi-circuit simultaneous output — 14 h at 15 kW, 27 h at 8 kW, 43 h at 5 kW.

IP54 Industrial Protection

Dust & splash proof (GB/T 4208-2017), -20°C ~ 50°C operation, altitude up to 2000 m.

Tow & Power in Minutes

A-frame hitch for qualified pickup / light trucks; park, engage the brake and supply power. Four-wheel chassis handles soft ground.

Fully Integrated Design

  • 8 independent industrial cable reels — multi-circuit output, tidy cable handling.
  • Integrated distribution cabinet with breakers, meters and protection modules.
  • Roller shutter side door — full access for operation, inspection and fast connection.
  • Two-axle four-wheel chassis with parking brake; A-frame hitch with anti-drop device.
  • Cluster-level quick swap — replace one battery cluster without stopping the others.
Sample photo · front view: 8 cable reels over the distribution cabinet

Key Specifications

ParameterValueBasis
Nominal energy241 kWh(15 × 16.08 kWh LFP)Design value
Rated output50 kW(55 kW / 10s peak)Design value
Output voltage220V 单相 / 380V 三相,纯正弦波Design value
Grid charging30 kW(0→100% ≈ 8h);选配 50 kW 直流快充 ≈ 5hDesign value
Emergency chargingExternal diesel generator up to 50 kWDesign value
Ingress protectionIP54(GB/T 4208-2017)Design value
Operating temperature-20°C ~ 50°C(>45°C 降额)Design value
Curb weight3200 kgEngineering estimate
Dimensions (L×W×H)3000 × 2200 × 2100 mm(±5mm)Engineering estimate
ChassisTwo-axle four-wheel trailer, A-frame hitchDesign value
Cell cycle life≥6000 次(0.5C / 25°C / 80% EOL)Per test report

Design value = design target; engineering estimate = pre-production projection. Items marked as design / estimate are subject to measured data and type-inspection reports before mass production.

Sample Vehicle Gallery

Click any photo to enlarge in high resolution.

Rear-side view · roller door open
Front view · reels & cabinet
Factory reception of the sample
Towed transit at dusk

Safety & Fire Protection

Three-Level Alarm Linkage

Over-voltage, under-voltage, over-current, high/low temperature, insulation faults and more are covered by graduated protection: Level 1 — derate 50% with audible/visual alert; Level 2 — current to 0A, charge/discharge stopped; Level 3 — relays cut off for full isolation. Low capacity uses load-limiting instead of cut-off, so your load never drops unexpectedly.

Per-Pack Aerosol Fire Suppression

Each battery PACK carries an independent S-type aerosol suppression unit: intelligent heat detection, auto activation, discharge within 6 s, full-flood coverage with minimal residue and low corrosion — physical + chemical dual suppression.

Full Lifecycle Service

3 yrWhole-machine warranty
5 yrCells: 5 years or 3,000 cycles
24 hRemote response; on-site within 48 h
10 yrCore spare parts supply commitment

FAQ

What driving license is required?

On public roads the combination (tractor + trailer) usually exceeds 4,500 kg GVM, so an A2 license is required. C6 only covers combinations under 4,500 kg and is not applicable.

Which vehicle can tow it?

A pickup or light truck with towing approval and a rated towing mass of at least 3,200 kg. Ordinary sedans / SUVs must not tow it on public roads.

How is it recharged?

Grid charging is the primary way: 30 kW, about 8 hours to full (optional 50 kW DC fast charge ≈ 5 h). In off-grid areas an external diesel generator (max 50 kW) can be used as a transitional backup.

How do you move it on site?

The unit has no self-drive power. On-site repositioning uses an optional detachable shunting device (site use only) or a forklift (≥4.8 t). Never use the shunting device on roads.

Can battery clusters be replaced separately?

Yes. 15 modular clusters are independent in grouping, cooling and protection; a faulty cluster can be replaced while the rest keep supplying power.

Can manual specs be used as contract values?

No. Values are marked as design values / engineering estimates; before mass production, measured data and type-inspection reports prevail. Contract commitments are subject to the signed agreement.

Power Follows You. Mission Delivered.

Hunan Mesian Safety Technology Co., Ltd. · Sales & rental: daily / weekly terms available

Business:hankxieyun@163.com · xieyun@meisian.cn

Send an Inquiry Download Manual PDF

Disclaimer: parameters are for reference only. Items marked "design value / engineering estimate" are subject to measured data and type-inspection reports before mass production, and to the signed contract. The manual is revised periodically — contact your sales manager for the latest version. © 2026 Hunan Mesian Safety Technology Co., Ltd.